Our Technology
CAREBra paired with CAREDevices acts as a sensor device attached to the surface of the skin
Receive and upload data to CAREBra APP via Bluetooth
Theories of heat conduction and metabolism are transformed into divisible data
CAREBra APP system generates analytical report
CAREDevice
1. Dynamic continuous monitoring probes for recording 3 types of body data
- Use a contact thermal sensor to measure local body temperature to form a 24H 10,000-point metabolic thermogram
- A non-contact heat sensor is used to measure local tissues to form a 10,000-point energy metabolism heat map
- Measure the rhythmic relationship between the non-contact metabolic heat and the density of water molecules
2. The body temperature rhythm formed by monitoring data every 5 seconds in each group can be used as a biomarker
3. Epidermal microenvironment monitoring: 3 sets of sensor data form a hierarchical warning of "breast biorhythm" with 0.001 accuracy.
Spectrum 1 - Dynamic temperature rhythm
Spectrum 2 - Dynamic biometabolic rhythm
Spectrum 3 - Dynamic humidity rhythm
Breast Health Indicator and CareTips
Your breast health will be expressed by a continous spectrum of health levels and the associated risk will be expressed as a simplified health grade, i.e., from Grade 1 as healthy breasts to Grade 5 which suggests a very high risks of breast cancer. The system will also make corresponding suggestions based on your health risk and gives recommendation on further medical diagnosis as necessary.
Indicator | CAREBra i.e. Breast Temperature Monitor (Note 1) |
B-mode ultrasound (Note 2) |
Mammography (Note 3) |
PET-CT (Note 4) |
MRT (Note 4) |
---|---|---|---|---|---|
Sensitivity | 97.70% | 79.3% | 86.67% | 83.30% | 88.50% |
Specificity | 76.60% | 89.00% | 54.05% | 66.70% | 84.90% |
- False positive | 23.40% | 11% | 45.95% | 33.30% | 15.10% |
- False negative | 2.3% | 21.70% | 13.33% | 16.70% | 11.50% |
- Positive Predictive Value | 76.8% | / | / | 88.20% | / |
- Negative Predictive Value | 97.70% | / | / | / | / |
Total concordance rate | 85.90% | 73.50% | 63.46% | 79.20% | 86.90% |
Data Sources:
Note 1: "Statistical Report on the Test of Breast Temperature Monitor"; "----Breast Biological Rhythm Monitoring System" (Shanghai Institute of Medical Device Testing)
Note 2: Zhu Pengfei, Zhao Gang, Cai Haifeng. Chinese Journal of Clinical Medicine 2014; 30(5) Color B-ultrasound results;
Note 3: The application value of molybdenum target in the diagnosis of breast cancer in Xinjiang Medical University (cited literature) Wang Chunyan;
Note 4: "Modern Hospital" 2008 Vol. 8 No. 4 p67-70.